Posted By Rich Miller On December 3, 2012 @ 8:00 am In | No Comments
[1]Facebook’s second data center on its North Carolina campus is ready for action. The 300,000 square foot facility features the social network’s latest technology. Click the image to see a larger version. (Photo: Rich Miller)
[2]Each data center features four data halls packed with row upon row of cabinets housing Facebook’s servers. This data hall ia in Facebook’s first building (FRC1), which was filled within nine months of opening. Fresh air enters the building through the second floor “cooling penthouse” and then enters the first-floor data halls through openings in the ceiling above the center aisle. The screens hanging from the ceiling are diffusers, which help circulate the cool air so it reaches the outer edges of each row of cabinets. (Photo: Rich Miller)
[3]The data halls in FRC1 are packed with Facebook’s “triplet” racks, which house server designs that contain two servers on each sled. Click the image to see a larger version. (Photo: Rich Miller)

In the data halls at FRC2, Facebook is testing the Open Rack, a single cabinet designed for trays that are 21 inches wide, instead of the standard 19 inches. Each cabinet includes three “power zones” served by a tray of power supplies (which are now separate from the servers) that tie into a bus bar in the rear of the enclosure. Server trays house three servers, each 2U in height, which plug into the bus bar. The design also includes a storage tray filled with JBOD (Just a Bunch of Disks), which can be seen immediately below the power supplies. (Photo: Rich Miller)
[4]This vast roof provides a sense of the scale of the Facebook facilities in Rutherford County, each of which measure a quarter-mile from end to end. Click the image for a larger version. (Photo: Rich Miller)
[5]The equipment yard behind each data center houses 16 diesel backup generators. Two generators are dedicated to keeping components of the cooling system online, with the remainder protecting IT loads. The two large storage tanks (at the rear of the photo) are the midway point of the yard, with eight more gensets on the far side. (Photo: Rich Miller)
Article printed from Data Center Knowledge: http://www.datacenterknowledge.com
URL to article: http://www.datacenterknowledge.com/inside-facebooks-north-carolina-data-center/
URLs in this post:
[1] Image: http://www.datacenterknowledge.com/wp-content/uploads/2012/12/fb-nc-900.jpg
[2] Image: http://www.datacenterknowledge.com/wp-content/uploads/2012/12/fb-nc-hall-900.jpg
[3] Image: http://www.datacenterknowledge.com/wp-content/uploads/2012/12/fb-racks-nc-900.jpg
[4] Image: http://www.datacenterknowledge.com/wp-content/uploads/2012/12/fb-nc-roof.jpg
[5] Image: http://www.datacenterknowledge.com/wp-content/uploads/2012/12/fb-nc-generators-900.jpg
Click here to print.
Copyright © 2011 Data Center Knowledge. All rights reserved.